In addition to some discrepancies between the module and the manual , one bigger fault could be detected. As described in the last paragraph, two tables have to be joined using the patient's number and the examinations' data which does not have to be exactly equal. This join is done incorrectly if the latest entry in the table progression (verlauf) is older than the according entry in the table ualbumin.